Lightning and Surge Protection 

 

 

 

HOME > SOLAR ELECTRIC > Lightning and surge protection

 

Preliminary announcement

Lightning and surge protection for the most difficult of installations.

Polar manufacturers an air coil type inductor that slows down the high voltage surge of electricity allowing the Metal Oxide Varistors (MOV) and Transzorbs (zeners) to be more effective in attenuating the current surge.

Polar offers specific voltage ranges: 

  • Up to 28 Vdc (for 12 V nominal systems)

  • Up to 55 Vdc (for 24 V nominal systems)

  • Up to 110 Vdc (for 48 V nominal systems)

  • Up to 28 Vdc (for 120 V nominal systems)

  • Higher voltages on request.

Be careful when selecting a surge protection device; if the clamping voltage is too high then the electronics connected to the system are not protected. It makes very little sense to have a 24 Vdc system and the surge protectors clamp at 120 Vdc; by the time the surge protection device clamps the equipment is already damaged.

Try a simple test (if you have the equipment) use an adjustable power supply and connect it to the surge protector, gradually raise the voltage and watch the current for a sudden rise (clamping voltage). You may be surprised how high the clamping voltage (it may be out of the range of your power supply) is on the common surge protectors used in the solar and marine industry.

We offer two standard size ranges of air coil, then we mate the air coil to the correct clamping voltage for the Transzorb and MOV. If larger currents are required then the coils can be installed in parallel.

We use both a MOV for their high energy clamping capacity, and the Transzorb for its faster response and more accurate clamping voltage. Using both technologies ends the discussions over which technology is better.

We offer two models with the following performances (at 25 C.), values are = - 10%:

Model 20A

Resistance is .0187 ohms
Inductance is 130 mh

Voltage drop at 10 amps is 0.21 V

Voltage drop at 20 amps is 0.42 V
Max recommended continuous current is 20 amps.
Weight: 2.13kg

 

 

Model 10A

Resistance is .0367 ohms
Inductance is 115 mh
Voltage drop at 5 amps is 0.20 V
Voltage drop at 10 amps is 0.40 V
Max recommended continuous current is 10 amps.
Weight: .65kg

 



Company | Telecommunication | Solar Electric | Metal Fabrication | Contract Manufacturing | Military
Products | Project Experience | Contract History | Contact Us | Direction/Map | What's New!
Global Impact | Technology Transfer | Guest Log | Site Map | Career Opportunities
 

Site Map

Copyright © 1999, All Right Reserved,  
Polar Power Inc.

 
If you are experiencing problems with this web site please contact webmaster@polarpowerinc.com
Revised: September 08, 2001 .